Also known as: HIB; Tetanus; Pneumococcal serotypes
Measurement of specific antibody production (spontaneous and post immunisation levels) is useful in the assessment of patients with suspected immune deficiency. However, pneumococcal polysaccharide antigens are T cell independent, which limits its utility in children less than 24 months.
Specimen requirements
Serum 1ml
Cost
Price on application
Laboratory turnaround time
7 days
Laboratory method
ELISA and Luminex
Reference range/units
Basal Protective Levels:
- Tetanus
0.15 IU/ml - Haemophilus influenza type B
0.15µg/ml - Pneumococcal antibody normal range
- 0-<3 years = no age range available
- 3-6 years = >7mg/L
- 7-10 years = >14mg/L
- >11 years = >20mg/L
Associated tests
Not applicable
Sample stability
2 months at 2-8ºC
Shipping and storage
UK and Ireland
Ambient temperature and first class post. Hays DX users please enquire via email below.
International
Ambient temperature if courier will deliver within 72 hours otherwise consider refrigerated transport. Freezing is not a requirement.
Ensure delivery Monday to Friday 09:00 - 17:30.
Further information and contact details
For further information, email immunologylab.enquiries@ouh.nhs.uk